Key Factors Affecting the Lifespan of DTRO Membranes
For sophisticated wastewater treatment systems, especially for difficult tasks like treating landfill leachate, disk tube reverse osmosis (DTRO) membranes are very important. The longevity of DTRO membranes can have a big effect on how well and how cheaply these treatment plants work. Not many things really matter when it comes to how long these membranes will last before they need to be fixed or changed. People who work at plants and do environmental work who want to get the most out of their DTRO systems need to know these things. Different factors determine how long a DTRO membrane lasts. These include the feed water quality, how it is used, how it is cleaned, and the material of the membrane itself. For these important parts to wear out faster, they should not be cleaned properly, be exposed to too many contaminants, or have the wrong pressure or flow rates. The membrane should also wear out first. Being careful with these things can help facilities keep the quality of their water treatment consistent, make their membranes last longer, and lower their running costs. This article looks at the delicate balance that must be struck to get the most performance and longevity out of DTRO membranes in tough wastewater treatment situations.

Feed Water Properties and Initial Treatment
The quality and make-up of the water that flows into the DTRO membranes are very important for how long they will last. Feed water that is very dirty or not properly prepared will quickly cause the membrane surface to become dirty and break down.
Load and Variability of Contaminants
There are often a lot of dissolved solids, organic substances, and suspended particles in landfill leachate and industrial wastewater. If these pollutants get on the membrane surface quickly, they can form a fouling layer. This layer makes it harder for water to pass through and needs more pressure to filter it properly. When there are rapid increases in contaminants or when new contaminants show up, pretreatment systems can become overloaded, which can cause membranes to break down more quickly.
Effectiveness of Pretreatment
To make the DTRO membrane last longer, it is important to do the right pretreatment. This could include:
- Flocculation and coagulation to get rid of solids that are in the air
- Adjusting the pH to make the membrane work better
- Ultrafiltration or microfiltration as a first stage in filtering
- Chemical treatments to stop biofouling and scaling
If pretreatment isn't done well, the membrane might quickly become dirty, which means more frequent cleaning cycles and perhaps permanent damage to the membrane structure.
Possibility of Scaling
Scales made of minerals are very bad for DTRO systems, especially when they are used to clean water that has a lot of calcium, magnesium, silica, or other substances that make scales. During reverse osmosis, when the water gets more concentrated, these minerals can settle on the membrane surface and form hard, crystalline deposits. This scaling not only makes it harder for things to pass through the membrane, but it can also damage its delicate structure.
System Design and Operational Parameters
How a DTRO system is built and used has a direct effect on how long the membrane lasts. To get the best performance out of the membranes while putting the least amount of stress on them, it's important to carefully adjust the operational settings.
Managing Pressure and Flux
DTRO membranes are made to work only within certain pressure and flux limits. Going over these limitations can cause the membrane structure to become more compact, which can permanently lose its capacity to let things through. On the other hand, working at too low of a pressure can make it harder to get rid of pollutants and make fouling more likely.
A well-designed system should have:
- Correctly sizing pressure vessels and pumps
- Setting up pressure control valves and monitoring tools
- Using variable frequency drives to manage flow with precision
Managing the temperature
The temperature of the water changes how thick the feed water is and how easily the membrane lets water through. Higher temperatures usually make permeate flux go up, but they can also speed up the chemical breakdown of the membrane material. Keeping the temperature in a continuous, ideal range is very important for balancing performance and longevity.
Speed of cross-flow
A good cross-flow velocity across the membrane surface helps keep foulants from building up and concentration polarization from happening. Not enough flow can cause the membrane to get dirty quickly, while too much speed can cause physical damage to the membrane via shear stresses.
Cleaning and Maintenance Instructions
For the DTRO membrane to work well and last longer, it needs to be cleaned regularly and well. If not done well, the cleaning process might also shorten the life of the membrane.
When and how often to clean?
The appropriate cleaning frequency depends on feed water quality and system operation. If you wait too long between cleanings, the foulants can stick to the membrane surface more firmly, making them harder to get rid of. Cleaning too much, on the other hand, can put the membrane under too much chemical stress.
Compatibility of Chemicals
It is important to choose cleaning chemicals carefully so that they work well with the membrane material. Using the wrong chemicals or the wrong amounts of them can permanently harm the structure of the membrane. Some common cleaning products are:
Acid remedies to get rid of scaling
Cleaning agents that use enzymes to clear up biological waste
When you start using new cleaning products, it's important to follow the manufacturer's instructions and do compatibility tests.
Ways to Clean Mechanically
Some DTRO systems may also benefit from mechanical cleaning methods like air scouring or membrane rotation, in addition to chemical cleaning. These methods can help get rid of foulants that aren't tightly adhered and make chemical cleaning work better. But you have to be careful not to use too much mechanical force, which could hurt the membrane surface.
Operators can greatly increase the life of their DTRO membranes by carefully controlling these three important factors: the quality of the feed water, the operational settings, and the cleaning processes. This not only cuts down on the cost of replacing things, but it also makes sure that the treatment works the same way every time. As the problems with treating wastewater change, especially in businesses that deal with complicated effluents, making DTRO membranes last longer becomes more and more important for operations that are both sustainable and cost-effective.
Questions That Are Often Asked
Q1: In general, how long does a DTRO membrane last?
How a DTRO membrane is used and how well it is taken care of can have a big effect on how long it lasts. In ideal conditions, a good DTRO membrane can last between 3 and 5 years. A membrane may only last one to three years in tough settings, like when it has to deal with leachate from landfills. You need to keep an eye on and take good care of a membrane to get the most life out of it.
Q2: How often should DTRO membranes be cleaned?
How often you clean depends on how well the system works and how good the feed water is. Most of the time, membranes need to be cleaned when either the differential pressure rises by 10 to 15% or the standardized permeate flow drops by 10 to 15%. This could mean cleaning the app every one to three months if it is very dirty. If the app isn't too dirty, cleaning it once every six to twelve months might be enough.
Q3: Can broken DTRO membranes be fixed?
A: DTRO membranes can sometimes be fixed by cleaning or fixing them by professionals who know how to do it. But most of the time, the only way to fix major damage or broad wear is to replace the membrane. If something is wrong, you should fix it right away to keep the system running well and stop more damage from happening.
Morui makes high-performance DTRO membranes for treating wastewater
Are you seeking for DTRO membranes that are strong and last a long time for your tough wastewater treatment jobs? Guangdong Morui Environmental Technology Co., Ltd. makes cutting-edge DTRO membrane systems that work best and last the longest. Our knowledgeable staff can help you choose the perfect membranes for your needs and provide you tips on how to best use and care for them.
Please email us at benson@guangdongmorui.com to find out more about our DTRO membrane products and how we can help you reach your wastewater treatment goals. Our sophisticated membrane technology can help you get the most out of your treatment systems by making them work better and last longer.
References
1. Zhang, L., and others (2021). "Improvements in disk tube reverse osmosis technology for cleaning up wastewater and getting resources back." 618,118632 in the Journal of Membrane Science.
2. Wang, Y., et al. (2020). "Controlling and preventing fouling when using high-pressure DTRO to treat landfill leachate." Chemosphere, 238, 124652.
3. Li, X., et al. (2019). "Performance and fouling characteristics of a new DTRO membrane system for treating wastewater with a lot of salt." Desalination, 467, 111–120.
4. Guo, W., and others (2018). "Comparison of the performance and fouling characteristics of reverse osmosis and integrated membrane systems in treating landfill leachate." Chemical Engineering Journal, 348, 616–623.
5. Tian, J. et al. (2017). "Membrane fouling in a membrane bioreactor: A review." Environmental Science and Pollution Research, 24(30), 23719–23735.
6. S. Judd (2016). "The current state of membrane bioreactor technology for treating industrial and municipal wastewater." Chemical Engineering Journal, 305, 37–45.

_1745823981883.webp)